• 0917-832-0004
  • inquiry@pebphilippines.com

Mon–Fri, 9:00 am – 5:00 pm

Cladding profile for roof and walls

Roof and wall sheets from SEICO Group, supplied with the steel frame so one team is responsible for the whole building envelope.

After many years of research and production, SEICO Group has developed roofing products with superior performance to meet the varied requirements of each project. PEB Philippines supplies them together with the frame, and DELTA Group's crews install them on site.

All four profiles are roll-formed from aluminum-zinc coated steel. The drawings show each profile's shape and dimensions in millimeters, and the ticked boxes show where it can be used. The roofing option drawings show the build-ups we offer, from a single sheet on purlins to sheets with insulation and an inner liner; the codes A1 to A7 refer to those build-up types.

1. Corrugated sheets (Ribs)

Ribs profiles: 5, 7, 9, 11 and 6 ribs, and where each can be used
Ribs profiles and their uses

Specifications

ProfileRib height (mm)Useful width (mm)Aluminum-zinc coating, AZ (g/m²)Steel grade (MPa)Thicknesses (mm)
5 Ribs331,00050, 100, 150, 200G300–G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
7 Ribs241,00050, 100, 150, 200G300–G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
9 Ribs211,00050, 100, 150, 200G300–G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
11 Ribs191,00050, 100, 150, 200G300–G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
6 Ribs3095050, 100, 150, 200G300–G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
6 Ribs, low151,08050, 100, 150, 200G300–G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
Ribs sheet roofing, wall and partition options
Ribs roofing, wall and partition options

2. Seamlock sheets

In the Seamlock roof system, the sheets are held down by clips that are screwed to the purlins. At each joint, the first sheet, the clip and the next sheet are folded together into one strong seam. No screws pass through the sheets, so there are no exposed fixings and far less risk of leaks, and the high ribs carry rainwater away instead of letting it spill over. SEICO Group rates Seamlock as its most storm-resistant roof.

Sheets are roll-formed to any length. For roofs longer than 12 m, the roll-forming machine is brought to the construction site.

Seamlock and Max Seam profiles and their clips
Seamlock and Max Seam profiles and clips

Specifications

ProfileRib height (mm)Useful width (mm)Aluminum-zinc coating, AZ (g/m²)Steel grade (MPa)Thicknesses (mm)
Seamlock6547050, 100, 150, (200)G300–G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
Max Seam11089050, 100, 150, (200)G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56

Static air pressure test (ASTM E1592)

ProfileSheet thickness (mm)Purlin spacing (mm)Test pressureWind speed (km/h)Storm level
Seamlock 4700.401,5001,400 N/m²17015
Max Seam 8900.451,500700 N/m²12212
Seamlock roofing options
Seamlock roofing options
Max Seam roofing options
Max Seam roofing options

3. Klip Lok sheets

Factory roofs from SEICO Group's Klip Lok catalog page
Kliplock type 1 and type 2 profiles and their clips
Kliplock profiles and clips

Specifications

ProfileRib height (mm)Useful width (mm)Aluminum-zinc coating, AZ (g/m²)Steel grade (MPa)Thicknesses (mm)
Kliplock type 14142050, 100, 150, (200)G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56
Kliplock type 24194050, 100, 150, (200)G5500.40, 0.45, 0.48, 0.50, 0.53, 0.56

Static air pressure test (ASTM E1592)

ProfileSheet thickness (mm)Purlin spacing (mm)Test pressureWind speed (km/h)Storm level
Kliplock 9400.401,500300 N/m²809
Klip Lok type 1 roofing, wall and partition options
Klip Lok type 1 options
Klip Lok type 2 roofing, wall and partition options
Klip Lok type 2 options

4. Deck sheets

Deck sheet types 1, 2 and 3
Deck sheet profiles and their uses

Specifications

ProfileRib height (mm)Useful width (mm)Aluminum-zinc coating, AZ (g/m²)Steel grade (MPa)Thicknesses (mm)
Deck type 15093080G3000.75, 0.95, 1.20
Deck type 2501,00080G3000.75, 0.95, 1.20
Deck type 37289080G3000.75, 0.95, 1.20

Figures from SEICO Group's product catalog. AZ is the aluminum-zinc coating mass; G300 and G550 are steel grades by minimum yield strength. Storm levels are on the Beaufort scale, as used in Vietnam.

Have a project in mind?

Tell us about your site, size and schedule, and our engineers will recommend a suitable steel building solution.

Hotline HOTLINE 0917-832-0004 Contact Us CONTACT US NOW