Designing a steel structure to American standards means checking its loads, members, connections, materials, welds and bolts against a linked set of United States codes and standards. Most of them come from the American Institute of Steel Construction (AISC), the American Society of Civil Engineers (ASCE), the American Welding Society (AWS) and ASTM International. The International Building Code (IBC) brings them together by adopting them by reference.
Why American standards
The AISC Specification for Structural Steel Buildings (ANSI/AISC 360) is an American National Standard, and the International Building Code adopts it by reference. AISC publishes it, together with its seismic provisions (AISC 341) and its Code of Standard Practice (AISC 303), as free downloads.
These standards are also used outside the United States. The steel chapter of the National Structural Code of the Philippines (NSCP) is based on AISC specifications. Owners of foreign-invested factories and warehouses often name AISC, AWS and ASTM standards in their project specifications, so that their consultants and inspectors can review the design against a framework they know.
The standards involved
| Standard | Published by | What it covers | Latest edition |
|---|---|---|---|
| International Building Code (IBC) | International Code Council | The model building code that adopts the standards below by reference. | 2027 |
| ASCE/SEI 7 Minimum Design Loads and Associated Criteria for Buildings and Other Structures | ASCE | Dead, live, snow, rain, ice, wind and seismic loads, and the combinations used to design for them. | 7-22 |
| ANSI/AISC 360 Specification for Structural Steel Buildings | AISC | Design of steel members and connections, stability and serviceability, plus requirements for fabrication, erection and quality control. | 360-22 |
| ANSI/AISC 341 Seismic Provisions for Structural Steel Buildings | AISC | Seismic force-resisting systems. It applies when the seismic response modification coefficient, R, is taken greater than 3. | 341-22 |
| ANSI/AISC 358 Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications | AISC | Beam-to-column connections already qualified for use in seismic moment frames. | 358-22 |
| ANSI/AISC 303 Code of Standard Practice for Steel Buildings and Bridges | AISC | Accepted trade practice when contracting for structural steel, such as drawings, tolerances and who is responsible for what. | 303-22 |
| AWS D1.1/D1.1M Structural Welding Code – Steel | AWS | Welded structures made from carbon and low-alloy steels: welding procedures, welder qualification, fabrication and inspection. | D1.1:2025 |
| RCSC Specification for Structural Joints Using High-Strength Bolts | Research Council on Structural Connections | Design, installation and inspection of high-strength bolted joints. | 2025 |
| AISI S100 North American Specification for the Design of Cold-Formed Steel Structural Members | Steel Deck Institute (formerly AISI) | Cold-formed steel members such as purlins and girts. | S100-24 |
| Metal Building Systems Manual | Metal Building Manufacturers Association (MBMA) | Load and design guidance for pre-engineered metal buildings. | 2024 |
Editions were checked in November 2026. A project uses the edition adopted by the local building authority or named in its specification, which may be an earlier one.
Two design methods: LRFD and ASD
AISC 360 sets out two ways of checking strength in one unified document. Both start from the same nominal strength, Rn, of each member or connection. They differ in where the safety margin is applied.
- Load and Resistance Factor Design (LRFD): the loads are multiplied by load factors, and the required strength must not exceed the design strength φRn, where φ is a resistance factor of less than 1.0.
- Allowable Strength Design (ASD): the loads are combined at service level, and the required strength must not exceed the allowable strength Rn/Ω, where Ω is a safety factor greater than 1.0.
The load combinations for each method come from ASCE 7.
How a design comes together
- Design criteria. The building code, the standards and their editions, the building's use, the site conditions and the owner's requirements are agreed and recorded first.
- Loads. Dead, live, wind, seismic and other environmental loads are found from ASCE 7. Equipment loads, such as overhead cranes, come from the project requirements. The loads are then combined using the LRFD or ASD load combinations.
- Analysis and stability. The frame is analyzed with a structural model. AISC 360 requires the design to account for stability, including second-order effects, initial imperfections and the reduction in stiffness as steel yields. Its direct analysis method is one way to do this.
- Member design. Columns, rafters, beams and bracing are checked for tension, compression, bending, shear and combined forces.
- Connections. Bolted and welded connections are designed to AISC 360, with bolting to the RCSC Specification and welding to AWS D1.1. In seismic force-resisting systems, AISC 341 and AISC 358 add requirements.
- Serviceability. Deflection, drift and vibration are checked so that the building works well in everyday use, not only at its strength limits.
- Drawings. Design, shop and erection drawings are prepared. AISC 303 sets out the usual responsibilities and the tolerances for fabrication and erection.
- Quality control. Material test certificates, welding procedures, welder qualifications and inspections of welds and bolted joints are recorded, following the quality requirements of AISC 360 and AWS D1.1.
Common materials
- ASTM A992: the preferred specification for wide-flange (W) shapes. Its minimum yield strength is 50 ksi (about 345 MPa), and its minimum tensile strength is 65 ksi (about 450 MPa).
- ASTM A572 Grade 50: high-strength low-alloy steel for plates and shapes, with a minimum yield strength of 50 ksi (about 345 MPa).
- ASTM A36: carbon steel for plates, angles and other shapes, with a minimum yield strength of 36 ksi (about 250 MPa).
- ASTM A500: cold-formed hollow structural sections (HSS).
- ASTM F3125: high-strength structural bolts. It includes Grades A325 and A490 and replaced the separate A325 and A490 standards.
Pre-engineered steel buildings
In a pre-engineered steel building, the main frames are designed to AISC 360, and the cold-formed purlins and girts to AISI S100. The MBMA Metal Building Systems Manual adds load and design guidance written for this type of building. Its 2024 edition conforms to the 2024 IBC and ASCE 7-22.
Working with PEB Philippines
SEICO Group designs steel structures to both American and Vietnamese standards, and PEB Philippines projects are also designed to NSCP 2015, the National Structural Code of the Philippines. Our Design page lists the standards and software our engineers use. The Steel structure pages describe what we build. To discuss a project designed to American standards, contact our team.
Where to find the standards
- AISC standards: AISC 360, 341, 358 and 303
- American Society of Civil Engineers: ASCE/SEI 7
- American Welding Society: AWS D1.1
- Research Council on Structural Connections: RCSC Specification
- Steel Deck Institute: AISI S100
- Metal Building Manufacturers Association: Metal Building Systems Manual
- International Code Council: International Building Code
- ASTM International: material and bolt specifications